Saturday, February 26, 2011

wind solar hybrid charge controller(3000W 48V~240V )

multiple protect functions
Automatic detection of voltage
PWM control
Multistage charging technology
Wind and Solar hybrid generation is quite advanced renewable energy system presently. Really, continue achieving green power to utilize for our word day and night.
The charge controller is used to manage power from windturbine and solar panel into accumulator battery intelligently and transfer automatically.
1.product features
· Series controller
· Voltage regulation
· Automatic detection of voltage
· PWM control
· Multistage charging technology
· Current compensated load disconnection
· Automatic load reconnection
· Temperature compensation

2.
Electronic protection functions
· Overcharge protection
· Deep discharge protection
· Reverse polarity protection of load, module and battery
· Automatic electronic fuse
· Short circuit protection of load and module
· Overvoltage protection at module input
· Open circuit protection without battery
· Reverse current protection at night
· Wind-turbine auto brake and brake switch for manual operation
· Battery overvoltage shutdown
3.Product tech-data
Model No.
IS-30-48
IS-30-96
IS-30-120
IS-30-240
Wind turbine power
3000 W
Solar rated power
1000 W
Rated Battery Voltage
48 V
96 V
120 V
240 V
Wind-turbine input power max.
5000 W
Wind-turbine input current max.
60 A
35 A
25 A
15 A
Over-charge voltage
58.8 V
116 V
144 V
264 V
Over-charge recovery voltage
56 V
110 V
138 V
288 V
Over-discharge Voltage
42.5 V
86 V
108 V
216 V
Over-discharge recovery Voltage
47 V
92 V
115 V
230 V
Method of control
Two way control with PWM
Free-load lost power
≤6 mA
Voltage lost on charging
≤0.26V
Voltage lost on discharge
≤0.15V
Display
* LCD show battery charging current; battery voltage; system operation status
* LED show battery situation ;device working status
Protection Mode
Solar cells reverse charging, solar cells anti-reverse connection, battery over-charging, battery over-discharge, battery anti-reverse connection, over-load, Load anti-reverse connection, wind-turbine current limited, wind-turbine rotation limited, manual brake switch equipped.
Over-load and short-circuit protection
1.25times 60sec./ 1.5times 5sec. action
ambient temperature
-25°C - +55°C
humidity
<85% RH without condensation
Dimension of main-device
415mm x 345mm x 160mm
Dimension of Dump-load Box
405mm X 200mm X 410mm
Weight of main-device
14 Kg
Weight of Dump-load Box
10 kg
Cooling Method
Cooling Fan

No comments:

Post a Comment