wind solar grid tie inverter 1kw-30kw
1.High transfer efficiency up tp 95%
2.Follow up utility grid in milliseconds
3.CE&ISO
Description,wind solar grid tie inverter 1kw-30kw
It is the core facility of solar power plant and wind turbine power plant. To sure the power plant can run stability, it highly require for the reliability of the grid-connected inverter. For the scurviness environment of the solar and wind turbine, the stability of DC supply is very bad, that more require to consummate the defend function of grid-connected inverter and strong capability to resist all kinds of impact.
Features of Grid tie inverter,
l Controlled by CPU, stability is reliable
l Able to follow up utility grid in milliseconds, complete synchronous with utility grid
l When utility tested by inverter in 3 seconds is normal, the inverter starts to work making sure the inverter won’t be damaged by frequency wave
l It will lock the unit automatically in less than 10ms when utility grid interrupted, over-voltage, or under-voltage
l When wind power over-voltage or solar intensity over strong with DC over voltage, inverter will automatically lock itself. When DC restores inverter will start to work automatically again
l Protection against short-circuit and overload
Specification of the on grid inverter
Specification for grid tie inverter
Model
NB-S,NB-W Series
Power range
1KW
2KW
3KW-5KW
10KW
20-30KW
50KW-200KW
DC voltage range
48V-120V
80V-250V
185V-300V
240-350V
300V-360V
600V -980V
THD
≤3%
Power factor
>0.99
DC to AC transfer efficiency
90~95%
Allowable electric net
175V~265V(single phase)
Voltage range(AC)
304V~450V(three phases)
Allowable electric net frequency range
50/60Hz
DC access type
Group terminal block +DC switch
AC access type
Group terminal block +AC switch
Communication ports
RS232, RS485, USB(optional)
Protections
short-circuit, reverse polarity, lone-island domino
effect and over-load protection
Operational environment temperature
10°C~+40°C
Electric net control
According to UL1741 and IEEE-2000 standards
Electromagnetism compatibleness
EN50081, PART1EN50082, and PART1
Utility grid disturbance
EN61000-3-0
Utility grid test
DIN VDE126